µêÆÌ»ù±¾×ÊÁÏÐÅÏ¢
|
ABB µÄ Conceptpower DPA 500 Ä£¿é»¯²»¼ä¶ÏµçÔ´£¨UPS£©ÊÇΪÖÐÐͺʹóÐÍÊý¾ÝÖÐÐÄÉè¼ÆµÄ£¬ËüÂú×ãÁË´Ó 100 ǧÍßµ½ 3 Õ×ÍߵĵçÁ¦ÐèÇ󣬲¢ÎªÄÇЩÐèÒªÁãÍ£»úʱ¼äÒÔ¼°µÍÓµÓгɱ¾µÄÓ¦ÓÃÌṩÁË***´ó¿ÉÓÃÐÔ¡£
Conceptpower DPA 500 ¿ÉÒÔÔÚÒ»¸öµ¥»ú¹ñÖÐʵÏÖ 100-500 kW£¨1-5 ¸öÄ£¿é£©µÄµçÁ¦±£»¤£¨×ÝÏò¿ÉÀ©Õ¹ÐÔ£©¡£»ú¹ñ¿ÉÒÔÔÚ²¢ÁªÅäÖÃÖÐÔËÐУ¬½¨Á¢Ò»¸ö¸ß´ï 3 MW µÄϵͳ£¨ºáÏò¿ÉÀ©Õ¹ÐÔ£©
ÏȽøµÄ UPS Éè¼ÆµÄ Conceptpower DPA 500 ¶ÔÓڹؼüµÄÓ¦ÓÿÉÒÔÌṩ***¸ß³Ì¶ÈµÄ±£»¤£¬¸ºÔØÒªÇó±ØÐëÌṩ¸ßÖÊÁ¿µÄµçÁ¦¡£¸Ã UPS ϵͳ²ÉÓ÷ÖÉ¢²¢Áª¼Ü¹¹£¬È·±£¸÷Ä£¿éÖ®¼ä¾ßÓÐÕæÕýµÄÈßÓ࣬¾ßÓÐ***¸ßµÄ¿É¿¿ÐԺͿÉÓÃ
ͨÓÃÊý¾Ý |
400V IEC |
ϵͳ¹¦ÂÊ·¶Î§ |
100 kW – 3000 kW |
±ê³Æ¹¦ÂÊ / Ä£¿é | 100 kW |
±ê³Æ¹¦ÂÊ / ¿ò¼Ü |
500 kW |
Êä³ö¹¦ÂÊÒòÊý |
1.0 |
²¢ÁªÅäÖà |
Ò»¸ö»ú¹ñ***¶à 5 ¸öÄ£¿é (500 kW) / ***¶à 6 ¸ö»ú¹ñ²¢Áª (3 MW) |
ÍØÆË½á¹¹ |
ÔÚÏßË«Ïòת»»£¬·Öɢʽ²¢Áª¼Ü¹¹ |
¿É·þÎñÐÔ | Íêȫǰ¶Ë |
ÊäÈë |
400V IEC |
±ê³ÆÊäÈëµçѹ |
3× 380 / 220 V + N£¬3× 400 / 230 V + N£¬3× 415 / 240 V + N |
µçѹÈݲ²Î¿¼ 400 / 230 V£© |
ÊÊÓÃÓÚ¸ºÔØ <100% (−10%£¬+15%)£¬<80% (−20%£¬+15%)£¬<60% (−30%£¬+15%) |
ƵÂÊ·¶Î§ |
35-70 Hz |
ÊäÈëÊ§Õæ THDi |
< 3.5 % |
¹¦ÂÊÒòÊý |
0.99 |
Êä³ö |
400V IEC |
¶î¶¨Êä³öµçѹ |
220/380, 230/400, 240/415 VAC |
µçÑ¹Ê§Õæ |
<±2%£¬´øÓÐÏßÐÔ¸ºÔØ / <±4%£¬´øÓзÇÏßÐÔ¸ºÔØ |
ƵÂÊ |
50 Hz »ò 60 Hz£¨¿ÉÑ¡Ôñ£© |
ЧÂÊ |
400V IEC |
×ÜЧÂÊ |
***¸ß 96% |
ÔÚ½ÚÄÜģʽÖÐ |
≥99% |
ͨÐÅ |
||
Óû§½çÃæ |
ͼÐλ¯´¥ÃþÆÁ£¨°´±ê×¼ÅäÖã¬Ã¿¸ö¿ò¼Ü´øÓÐÒ»¸ö£© |
|
ͨÐÅ¶Ë¿Ú |
USB£¬RS-232£¬ÎÞµçÊÆ´¥µã£¬SNMP£¨¿ÉÑ¡£© |
|
¿Í»§½çÃæ |
Ô¶³Ì¹Ø»ú£¬·¢µç»ú×é½çÃæ£¬ÍⲿÅÔ·´¥µã |
ºÏ¹æ |
400V IEC |
°²È«ÐÔ |
IEC/EN 62040-1 |
EMC |
IEC/EN 62040-2 |
ÐÔÄÜ |
IEC/EN 62040-3 |
ÖÆÔì |
ISO 9001:2015£¬ISO 14001:2015£¬OHSAS18001 |
¼¼Êõ¹æ¸ñÈçÓиü¸Ä£¬Ë¡²»ÁíÐÐ֪ͨ¡£
General data |
400V IEC | 480V UL | |
System power range |
100 kW – 3000 kW |
||
UPS module rated power | 100 kW | ||
UPS cabinet rated power |
500 kW |
300 kW / 500 kW | |
UPS output rated PF |
1.0 |
||
Parallel configuration |
500 kW Cabinet: |
300 kW Cabinet: Up to 3 modules in one cabinet Up to 4 cabinets in parallel/1.2MW 500 kW Cabinet: Up to 5 modules in one cabinet Up to 6 cabinets in paralle/3MW |
|
Wiring |
3ph + N + PE |
3ph + PE |
|
UPS type |
Modular, Decentralized Parallel Architecture (DPA) |
||
Topology |
Online double conversion |
||
Serviceability | Front access only |
Input |
400V IEC | 480V UL |
Nominal input voltage |
220/380, 230/400, |
3 x 480VAC |
Voltage range |
< 100% (-10%,+15%) |
|
Frequency range |
35-70 Hz |
60 Hz |
Current THD at 100% load |
< 3.5 % |
|
Power Factor at 100% load |
0.99 |
Output |
400V IEC | 480V UL |
Rated output voltage |
220/380, 230/400, 240/415 VAC |
3 x 480VAC |
Voltage THD (with linear load) |
< 2 % |
|
Frequency |
50 or 60 Hz (selectable) |
60 Hz |
Efficiency |
400V IEC | 480V UL |
Online double conversion |
Up to 96% |
>96% |
Eco-mode |
≥99% |
Communications |
||
User interface |
Graphical touch screen (one per |
|
Communication ports (optional) |
USB, RS-232, potential-free contacts, SNMP |
|
Customer interface (400 V IEC only) |
Remote shutdown, gen-set interface, external bypass contact |
Compliancy |
400V IEC | 480V UL |
Safety |
IEC/EN 62040-1 |
UL 1778 5th edition, CSA C22.2 No. 107.3-14 3rd Ed. |
EMC |
IEC/EN 62040-2 |
IEC/EN 62040-2 C3 |
Performance |
IEC/EN 62040-3 |
IEC/EN 62040-3 |
Manufacturing |
ISO 9001:2008, ISO 14001:2004 |
ISO 9001:2008 |
¼¼Êõ¹æ¸ñÈçÓиü¸Ä£¬Ë¡²»ÁíÐÐ֪ͨ¡£
Æ·ÀàÆëÈ«
Ê¡ÐÄÊ¡Á¦£¬Ò»Õ¾¹ºÆë
Ò»¶ÔÒ»¿Í·þ
Ñ¡ÐÍѯ¼Û£¬¿ìËÙÏìÓ¦
»õÆÚ±£ÕÏ
¶à²ÖÖ±·¢£¬»õÆÚÎÞÓÇ
ÕýÆ·»õÔ´
ÕýÆ·±£ÕÏ£¬³ÏÐÅ·þÎñ