Ò»°ãÌØÐÔ£º |
Sensor range |
up to 150 mm (KLR-C02-2,2-2,0-K146) |
Detection range |
up to 450 mm (KLE-C01-2,2-2,0-K116) |
Light source |
LED |
Light type |
modulated visible red light , 660 nm |
Gang mounting |
maximum 20 units |
¹¦Äܰ²È«ÐÔ²ÎÊý£º |
MTTFd |
500 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
ָʾµÆ/²Ù×÷¼ü£º |
Function indicator |
LED yellow: static illumination switching state, flashes when falling short of the stability control |
Control elements |
Button (Mode) for menu choice ; Button (Set) for Teach-In ; Button (Up/Down) for fine adjusting and parameterization |
µçÆøÌØÐÔ£º |
Operating voltage |
10 ... 30 V DC |
Êä³ö£º |
Switching type |
light/dark on selectable programmable |
Signal output |
1 push-pull (4 in 1) output NPN/PNP , short-circuit protected |
Óë±ê×¼ºÍ¹æ·¶ÌåϵµÄÒ»ÖÂÐÔ£º |
Standard conformity |
|
|
Product standard |
EN 60947-5-2:2007
IEC 60947-5-2:2007 |
»úÐµÌØÐÔ£º |
Degree of protection |
IP50 |
Connection |
200 mm, PVC cable with M8 connector, 4-pin |
Material |
|
|
Housing |
PC |